RESIDENTIAL SYSTEMS 1kW to 8kW - 1Ф

Rotosol Invert offers a complete range of single phase inverters for
residential roof-top systems.

product image
ELECTRICAL SPECIFICATION RIS1K RIS2K RIS3K RIS4K RIS5K RIS6K RIS8K

INPUT(DC)

Max DC Power (W) 1100 2200 3300 4400 5500 6600 8800
Max DC Voltage (V) 450 500 550 550 550 550 580
Rated / Recommended Voltage WI 360 360 360 360 360 380 450
MPPT DC Voltage Range (V) 50-400 120-400 120-450 120-450 120-450 120-450 120-480
Start up DC Voltage (V) 60 150 150 150 150 150 150
Max DC Current (A) 10 12 12*2 16 *2 18*2 18*2 18*2
Number of MPPT Tracker 1 1 2 2 2 2 2
Number of DC Connections (set) 1 1 2 2 2 2 2+1

OUTPUT(AC)

Max AC Power (W) 1050 2100 3100 4100 5100 6100 8000
Nominal AC Power (W) 1000 2000 3000 4000 5000 6000 8000
Max AC Current (A) 6 12 15 20 23 28 33
Nominal AC Current (A) 6 10 13 18 22 26 32
Nominal AC Voltage (V) 220/230
Nominal AC Frequency (Hz) 50/60
Power Factor -0.95 ~ +0.95
Output current THD < 3%

Power consumption

Power consumption at Night (W) < 0.2 < 1 < 1 < 1 < 1 < 1 < 1
Power consumption at Standby (W) 6

Power Efficiency

Max Efficiency 96.50% 97.70% 98.03% 98.03% 98.10% 98.10% 98.20%
Euro Efficiency 96.00% 96.60% 97.60% 97.60% 97.60% 97.60% 97.80%
MPPT Efficiency >99.90% >99.90% >99.90% >99.90% >99.90% >99.90% >99.90%

Safety and protection

Safety Standard EN/IEC 62109-1/-2
EMC Standard EN/IEC 61000-6, EN/IEC 61000-3
Anti-islanding Protection Internal

General information

Dimensions (W*H*D) (mm) 320*345*170 460*345*170 560*345*170
Enclosure IP65
RCD Internal
Weight (kg) 9 17 18.5
Ambient Temperature Range -25°C ~ +60°C
Relative humidity 0%~100%
Topology Transformerless
Communication Interface RS485 / WIFI / Wired Ethernet / GPRS (Optional)
Cooling Concept Convection
Noise Emission (dB) < 28 < 40
Maximum Altitude (above sea level) (m) Up to 2000m without derating